Pump performance curves for YT-T-2520

Pump performance curves for YT-T-3015
FEATURES
1. The control box and the machine are separated to increase
thermal insulation and extend the parts¡¯ life span.
2. The internal oil circulation pipes will automatically fill up the oil
and eliminate entrapped air upon startup of the machine, which
prevents dry running which can cause heater and motor failure.
3. The "YAMATAKE" P.I.D microcomputer automatic algorithm
imported from Japan is used for temperature control to ensure
accuracy and stability, and keep the exit temperature difference
within ¡¾0.5¡ÆC.
4. FUJI, L.G, and O.D.E imported parts are used for all heater
components.
5. SPECK, CIRO and TECO oil pumps are used for max heating/
cooling speed, saving electricity cost.
A. Temperature deviation and warning indicator:
When the exit temperature differs from the setting by more than
2¡ÆC~4¡ÆC (deviation value can be set), the buzzer and indicator
will be activated.
B. Force cooling:
Press this button before ceasing operation; the heated circulation
oil will be forced to cool down automatically.
C. Automatic oil discharge
When the heated circulation oil cools down to room temperature,
press this button to discharge all oil in the pipes between the
mold temperature controller and mold into the oil tank by air.
Safety protection and indicator system
1. Phase protection of power supply
2. Leak-proof protection switch
3. Pump reversal protection and indicator
4. Pump overload protection and indicator
5. Over-heat protection and indicator
6. Hot circulation oil BY-PASS pressure releasing loop
7. Temperature abnormality alarm and indicator (FS series)
8. Error alarm and buzzer
9. Oil shortage protection and indicator
Optional parts
2. Thermocouple for connecting to external device
3. Thermometer display for oil return temperature
4. Voltage abnormality protection switch
5. Teflon tube
Specification/model |
YT-T2010F
YT-T2010FS |
YT-T2010FD
YT-T2010FSD |
YT-T2020F
YT-T2020FS |
YT-T2020FD
YT-T2020FSD |
YT-T2520F
YT-T2520FS |
YT-T3015F
YT-T3015FS |
Power supply (V/HZ/3¨ª¨ª) |
AC220~440 50/60 |
Max. Temp. (¡É) |
200 |
250 |
300 |
Min. Temp. (¡É) |
60 |
80 |
Medium for heat |
Oil |
Heating energy(KW) |
9 |
9×2 |
9 |
9×2 |
9 |
Cooling energy(Kcal/hr) |
3000 |
3000×2 |
3000 |
3000×2 |
6000 |
Cooling method |
Indirect cooling |
Accuracy of Temp. control (¡É) |
±0.5 |
Oil tank capacity(L) |
10 |
15 |
10 |
15 |
10 |
Pump hosepower (KW) |
0.75 |
0.75×2 |
1.5 |
1.5×2 |
1.5 |
1.1 |
Pump Max. flow (L/min) |
50 |
45 |
110 |
450 |
50 |
60 |
55 |
110 |
500 |
60 |
Pump Max. pressure (kg/c§³) |
50 |
3.2 |
5.0 |
2.2 |
5.5 |
60 |
4.0 |
5.0 |
2.3 |
6.5 |
Max. Power(KW) |
9.75 |
19 |
10.5 |
21 |
10.5 |
10.1 |
Pressure of external cooling water (kg) |
1.0 |
Size of cooling water tube(inch) |
1/2 |
Size of hot water tube (inch) |
4×4, 3/8 OR 1×1, 3/4 |
Size of mold Temp. controller L¡¿W¡¿H(mm) |
730×300×750 |
890×400×850 |
730×300×750 |
890×400×850 |
730×300×750 |
Weight of mold Temp. controller (kg) |
73 |
120 |
75 |
130 |
80 |
|